Parameters
7.3 Parameters
p1010[0...n]

CO: Fixed speed setpoint 10 / n_set_fixed 10

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 10.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1011[0...n]

CO: Fixed speed setpoint 11 / n_set_fixed 11

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 11.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1012[0...n]

CO: Fixed speed setpoint 12 / n_set_fixed 12

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 12.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1013[0...n]

CO: Fixed speed setpoint 13 / n_set_fixed 13

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 13.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
464
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
SINAMICS G120XA converter

Advertisement

Table of Contents
loading

Table of Contents