Motor Data Identification And Speed Controller Optimization - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

r0047
Motor data identification and speed controller optimization / MotID and n_opt
Access level: 1
Can be changed: -
Unit group: -
Min:
0
Description:
Displays the actual status for the motor data identification (stationary measurement) and the speed controller
optimization (rotating measurement).
Value:
0:
115:
120:
140:
150:
170:
195:
200:
220:
230:
240:
250:
260:
270:
290:
300:
r0047
Motor data identification and speed controller optimization / MotID and n_opt
CUG120XA_USS
Access level: 1
(PM330)
Can be changed: -
Unit group: -
Min:
0
Description:
Displays the actual status for the motor data identification (stationary measurement) and the speed controller
optimization (rotating measurement).
Value:
0:
115:
120:
140:
150:
170:
195:
200:
220:
230:
240:
250:
270:
290:
295:
300:
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
No measurement
Measurement q leakage inductance (part 2)
Speed controller optimization (vibration test)
Calculate speed controller setting
Measurement moment of inertia
Measurement magnetizing current and saturation characteristic
Measurement q leakage inductance (part 1)
Rotating measurement selected
identification leakage inductance
Identification rotor time constant
Identification stator inductance
Identification stator inductance LQLD
Identification circuit
Identification stator resistance
Identification valve lockout time
Stationary measurement selected
No measurement
Measurement q leakage inductance (part 2)
Speed controller optimization (vibration test)
Calculate speed controller setting
Measurement moment of inertia
Measurement magnetizing current and saturation characteristic
Measurement q leakage inductance (part 1)
Rotating measurement selected
identification leakage inductance
Identification rotor time constant
Identification stator inductance
Identification stator inductance LQLD
Identification stator resistance
Identification valve lockout time
Calibration output voltage measurement
Stationary measurement selected
Calculated: -
Scaling: -
Unit selection: -
Max:
300
Calculated: -
Scaling: -
Unit selection: -
Max:
300
Parameters
7.3 Parameters
Data type: Integer16
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Integer16
Dynamic index: -
Function diagram: -
Factory setting:
-
363

Advertisement

Table of Contents
loading