Dependency:
The rated slip is calculated from the rated frequency, rated speed and number of pole pairs.
See also: p0310, p0311, r0313
Note
The parameter is not used for synchronous motors (p0300 = 2xx).
r0331[0...n]
Actual motor magnetizing current/short-circuit current / Mot I_mag_rtd act
Access level: 3
Can be changed: -
Unit group: -
Min:
- [Arms]
Description:
Induction motor:
Displays the rated magnetizing current from p0320.
For p0320 = 0, the internally calculated magnetizing current is displayed.
Synchronous motor:
Displays the rated short-circuit current from p0320.
Dependency:
If p0320 was not entered, then the parameter is calculated from the rating plate parameters.
r0332[0...n]
Rated motor power factor / Mot cos phi rated
Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the rated power factor for induction motors.
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1, 2):
For p0309 = 0, the internally calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency:
If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note
The parameter is not used for synchronous motors (p0300 = 2xx).
r0333[0...n]

Rated motor torque / Mot M_rated

Access level: 3
Can be changed: -
Unit group: 7_4
Min:
- [Nm]
Description:
Displays the rated motor torque.
Dependency:
IEC drives (p0100 = 0): unit Nm
NEMA drives (p0100 = 1): unit lbf ft
Note
For induction motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328.
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Calculated: -
Scaling: -
Unit selection: -
Max:
- [Arms]
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: p0100
Max:
- [Nm]
Parameters
7.3 Parameters
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 6722
Factory setting:
- [Arms]
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
Factory setting:
-
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: -
Factory setting:
- [Nm]
397