Actual Macro / Actual Macro; Bico Interconnections Search Signal Source / Bico S_Src Srch; Bico Interconnections Signal Source Search Count / Bico S_Src Srchqty - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

01
02
03
Dependency:
See also: p9400
Note
For bit 01, 00:
Bit 1/0 = 0/0: No memory card inserted (corresponds to p9400 = 0).
Bit 1/0 = 0/1: "Safe removal" possible (corresponds to p9400 = 3).
Bit 1/0 = 1/0: Status not possible.
Bit 1/0 = 1/1: Memory card inserted (corresponds to p9400 = 1, 2, 100).
For bit 02, 00:
Bit 2/0 = 0/0: No memory card inserted.
Bit 2/0 = 0/1: Memory card inserted, but not a SIEMENS memory card.
Bit 2/0 = 1/0: Status not possible.
Bit 2/0 = 1/1: SIEMENS memory card inserted.
r9463

Actual macro / Actual macro

Access level: 3
Can be changed: -
Unit group: -
Min:
0
Description:
Displays the set valid macro.
Note
A value of 0 is displayed if a parameter set by a macro is changed.
p9484

BICO interconnections search signal source / BICO S_src srch

Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the number
(r9485) and the first index (r9486).
Dependency:
See also: r9485, r9486
r9485

BICO interconnections signal source search count / BICO S_src srchQty

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
See also: p9484, r9486
Note
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Memory card activated
SIEMENS memory card
Memory card as USB data storage medium from the PC used Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max:
999999
Calculated: -
Scaling: -
Unit selection: -
Max:
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Parameters
7.3 Parameters
No
-
No
-
No
-
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Unsigned16
Dynamic index: -
Function diagram: -
Factory setting:
-
683