Extending The Exception List For Know-How Protection; Absolute Know-How Protection; Activating And Deactivating Know-How Protection; Conditions For Know-How Protection - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

Number
p11026
p11126
p11226
8.6.2

Extending the exception list for know-how protection

In the factory setting, the exception list only includes the password for know-how protection.
Before activating know-how protection, you can additionally enter the adjustable parameters in
the exception list, which must still be able to be read and changed by end users – even if know-
how protection has been activated.
You do not need to change the exception list, if, with exception of the password, you do not
require additional adjustable parameters in the exception list.

Absolute know-how protection

If you remove password p7766 from the exception list, it is no longer possible to enter or change
the password for know-how protection.
You must reset the converter to the factory settings in order to be able to gain access to the
converter adjustable parameters. When restoring the factory settings, you lose what you have
configured in the converter, and you must recommission the converter.
Parameter
Parameter
p7763
p7764[0...p7763]
8.6.3

Activating and deactivating know-how protection

Conditions for know-how protection

● The converter has now been commissioned.
● You have generated the exception list for know-how protection.
● To guarantee know-how protection, you must ensure that the project does not remain at the
end user as a file.
Preventing data reconstruction from the memory card
As soon as know-how protection has been activated, the converter only backs up encrypted
data to the memory card.
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Name
Free tec_ctrl 0 unit selection / Ftec0 unit sel
Free tec_ctrl 1 unit selection / Ftec1 unit sel
Free tec_ctrl 2 unit selection / Ftec2 unit sel
Description
KHP OEM exception list, number of indices for p7764
KHP OEM exception list
p7766 is the password for know-how protection
Saving the settings and series commissioning
8.6 Know-how protection
Factory setting
1
[0] 7766
[1...499] 0