Siemens SINAMICS G120XA Operating Instructions Manual page 368

Table of Contents

Advertisement

Parameters
7.3 Parameters
Note
The following status bits are displayed in r0053:
Bit 01: r2197 Bit 5 (negated)
Bit 02: r2197 Bit 0 (negated)
Bit 03: r2197 Bit 8
Bit 04: r2197 Bit 2
Bit 05: r2197 Bit 1
Bit 06: r2197 Bit 4
Bit 07: r2197 Bit 9
Bit 08: r2197 Bit 10
Bit 09: r1199 Bit 2 (negated)
Bit 10: r2349 Bit 10
Bit 11: r2349 Bit 11
r0053.0...11
CO/BO: Status word 2 / ZSW 2
CUG120XA_USS (DC
Access level: 2
braking)
Can be changed: -
Unit group: -
Min:
-
Description:
Display and BICO output for status word 2.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
NOTICE
p2081 is used to define the signal sources of the PROFIdrive status word interconnection.
Note
The following status bits are displayed in r0053:
Bit 00: r1239 Bit 8
Bit 01: r2197 Bit 5 (negated)
Bit 02: r2197 Bit 0 (negated)
Bit 03: r2197 Bit 8
Bit 04: r2197 Bit 2
Bit 05: r2197 Bit 1
Bit 06: r2197 Bit 4
Bit 07: r2197 Bit 9
Bit 08: r2197 Bit 10
Bit 09: r1199 Bit 2 (negated)
Bit 10: r2349 Bit 10
Bit 11: r2349 Bit 11
366
Signal name
DC braking active
|n_act| > p1226 (n_standstill)
|n_act| > p1080 (n_min)
I_act >= p2170
|n_act| > p2155
|n_act| <= p2155
|n_act| >= r1119 (n_set)
Vdc <= p2172
Vdc > p2172
Ramp-up/ramp-down completed
Technology controller output at the lower limit
Technology controller output at the upper limit
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: Unsigned16
Dynamic index: -
Function diagram: -
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
SINAMICS G120XA converter

Advertisement

Table of Contents
loading

Table of Contents