BI: ESM activation signal source
p3880, 653
BI: ESM direction of rotation signal source
p3883, 654
BI: External alarm 1
p2112[0...n], 580
BI: External alarm 2
p2116[0...n], 580
BI: External alarm 3
p2117[0...n], 581
BI: External fault 1
p2106[0...n], 578
BI: External fault 2
p2107[0...n], 578
BI: External fault 3
p2108[0...n], 578, 579
BI: External fault 3 enable
p3111[0...n], 638
BI: External fault 3 enable negated
p3112[0...n], 638
BI: Fixed speed setpoint selection Bit 0
p1020[0...n], 465
BI: Fixed speed setpoint selection Bit 1
p1021[0...n], 466
BI: Fixed speed setpoint selection Bit 2
p1022[0...n], 466
BI: Fixed speed setpoint selection Bit 3
p1023[0...n], 466
BI: Flying restart enable signal source
p1201[0...n], 489
BI: Free tec_ctrl 0 enable
p11000, 684
BI: Free tec_ctrl 1 enable
p11100, 691
BI: Free tec_ctrl 2 enable
p11200, 698
BI: Frost protection enable
p29622[0...n], 717
BI: Hold technology controller integrator
p2286[0...n], 617
BI: Inhibit master control
p0806, 444
BI: Inhibit negative direction
p1110[0...n], 480
BI: Inhibit positive direction
p1111[0...n], 480
BI: Jog bit 0
p1055[0...n], 472
BI: Jog bit 1
p1056[0...n], 472
BI: Limit switch minus
p3343[0...n], 649
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
BI: Limit switch plus
p3342[0...n], 649
BI: Limit switch start
p3340[0...n], 648
BI: Line contactor feedback signal
p0860, 452
BI: Load monitoring failure detection
p3232[0...n], 643
BI: Motor stall monitoring enable (negated)
p2144[0...n], 588
BI: Motorized potentiometer accept setting value
p1043[0...n], 470
BI: Motorized potentiometer inversion
p1039[0...n], 469
BI: Motorized potentiometer lower setpoint
p1036[0...n], 468
BI: Motorized potentiometer manual/automatic
p1041[0...n], 470
BI: Motorized potentiometer setpoint raise
p1035[0...n], 468
BI: Multi-pump control motor under repair
p29543[0...3], 711
BI: No coast-down / coast-down (OFF2) signal source
1
p0844[0...n], 448
BI: No coast-down / coast-down (OFF2) signal source
2
p0845[0...n], 449
BI: No Quick Stop / Quick Stop (OFF3) signal source
1
p0848[0...n], 450
BI: No Quick Stop / Quick Stop (OFF3) signal source
2
p0849[0...n], 450
BI: ON / OFF (OFF1)
p0840[0...n], 448
BI: ON/OFF1 (OFF1)
p29651[0...n], 722
BI: ON/OFF2 (OFF2)
p29652[0...n], 722
BI: Ramp-function generator, accept setpoint
p29642, 721
BI: Ramp-function generator, accept setting value
p1143[0...n], 487
BI: RFG active
p2148[0...n], 589
BI: Select IOP manual mode
p8558, 681
BI: Setpoint inversion
p1113[0...n], 481
BI: Technology controller enable
p2200[0...n], 602