Siemens SINAMICS G120XA Operating Instructions Manual page 898

Table of Contents

Advertisement

Index
CO: CU analog inputs actual value in percent
r0755[0...3], 432
CO: CU analog inputs input voltage/current actual
r0752[0...3], 431
CO: Current actual value field-generating
r0076, 373
CO: Current actual value torque-generating
r0078, 373
CO: Current setpoint field-generating
r0075, 372
CO: Current setpoint torque-generating
r0077, 373
CO: DC link voltage smoothed
r0026, 355
CO: Energy display
r0039[0...2], 359
CO: Extented setpoint channel setpoint output
r29641, 721
CO: Fieldbus analog outputs
p0791[0...2], 440
CO: Fixed speed setpoint 1
p1001[0...n], 461
CO: Fixed speed setpoint 10
p1010[0...n], 464
CO: Fixed speed setpoint 11
p1011[0...n], 464
CO: Fixed speed setpoint 12
p1012[0...n], 464
CO: Fixed speed setpoint 13
p1013[0...n], 464
CO: Fixed speed setpoint 14
p1014[0...n], 465
CO: Fixed speed setpoint 15
p1015[0...n], 465
CO: Fixed speed setpoint 2
p1002[0...n], 462
CO: Fixed speed setpoint 3
p1003[0...n], 462
CO: Fixed speed setpoint 4
p1004[0...n], 462
CO: Fixed speed setpoint 5
p1005[0...n], 462
CO: Fixed speed setpoint 6
p1006[0...n], 463
CO: Fixed speed setpoint 7
p1007[0...n], 463
CO: Fixed speed setpoint 8
p1008[0...n], 463
CO: Fixed speed setpoint 9
p1009[0...n], 463
CO: Fixed speed setpoint effective
r1024, 467
896
CO: Fixed value 1 [%]
p2900[0...n], 635
CO: Fixed value 2 [%]
p2901[0...n], 636
CO: Fixed value M [Nm]
p2930[0...n], 636
CO: Fixed values [%]
r2902[0...14], 636
CO: Flux setpoint
p1570[0...n], 528, 529
CO: Free tec_ctrl 0 actual value after limiter
r11072, 689
CO: Free tec_ctrl 0 limit maximum
p11091, 690
CO: Free tec_ctrl 0 limit minimum
p11092, 690
CO: Free tec_ctrl 0 output signal
r11094, 691
CO: Free tec_ctrl 0 setpoint after ramp-function
generator
r11060, 687
CO: Free tec_ctrl 0 system deviation
r11073, 689
CO: Free tec_ctrl 1 actual value after limiter
r11172, 696
CO: Free tec_ctrl 1 limit maximum
p11191, 697
CO: Free tec_ctrl 1 limit minimum
p11192, 697
CO: Free tec_ctrl 1 output signal
r11194, 698
CO: Free tec_ctrl 1 setpoint after ramp-function
generator
r11160, 694
CO: Free tec_ctrl 1 system deviation
r11173, 696
CO: Free tec_ctrl 2 actual value after limiter
r11272, 703
CO: Free tec_ctrl 2 limit maximum
p11291, 704
CO: Free tec_ctrl 2 limit minimum
p11292, 704
CO: Free tec_ctrl 2 output signal
r11294, 705
CO: Free tec_ctrl 2 setpoint after ramp-function
generator
r11260, 701
CO: Free tec_ctrl 2 system deviation
r11273, 703
CO: Hibernation mode output speed actual
r2397[0...1], 634
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
SINAMICS G120XA converter

Advertisement

Table of Contents
loading

Table of Contents