Unit Group And Unit Selection; Data Type; Scaling - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

CO
CO/BO
Can be changed
"-"
C(x)
U
T

Unit group and unit selection

For parameters where the unit can be switched over.
"Unit group": to which group does the parameter belong?
"Unit selection": with which parameter do you switch over the unit?

Data type

● Integer8
● Integer16
● Integer32
● Unsigned8
● Unsigned16
● Unsigned32
● FloatingPoint32

Scaling

Specification of the reference variable with which a signal value is automatically converted with
a BICO interconnection.
The following reference variables are available:
● p2000 ... p2003: Reference speed, reference voltage, etc.
● PERCENT: 1.0 = 100%
● 4000H: 4000 hex = 100 % (word) or 4000 0000 hex = 100 % (double word)
More information
Firmware version: V1.00
Firmware version of the basic system V04712502_1000100
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Connector output
Connector/binector output
Interconnecting signals in the converter (Page 882)
The parameter can be changed in any state, and the change becomes imme‐
diately effective.
The parameter can only be changed for the following settings:
C: p0010 > 0
C(x): p0010 = x
The motor is switched on
The motor is switched off and p0010 = 0
I8
I16
I32
U8
U16
U32
Float
7.2 Explanation of the detailed parameter list
8-bit integer
16-bit integer
32-bit integer
8-bit without sign
16-bit without sign
32-bit without sign
32-bit floating-point number
Parameters
351

Advertisement

Table of Contents
loading

Table of Contents