PM330 digital outputs status / PM330 DO status

CUG120XA_USS
Access level: 3
(PM330)
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the status of the digital outputs of Power Module 330 (PM330).
Bit field:
Bit
00
01
Note
DO: Digital Output
p4095

PM330 digital inputs simulation mode / PM330 DI sim_mode

CUG120XA_USS
Access level: 3
(PM330)
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the simulation mode for digital inputs of the PM330 power unit.
Bit field:
Bit
00
01
02
03
Dependency:
The setpoint for the input signals is specified using p4096.
See also: p4096
Note
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
p4096

PM330 digital inputs simulation mode setpoint / PM330 DI sim setp

CUG120XA_USS
Access level: 3
(PM330)
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the setpoint for the input signals in the digital input simulation mode of the PM330 power unit.
Bit field:
Bit
00
01
02
03
Dependency:
The simulation of a digital input is selected using p4095.
See also: p4095
Note
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Signal name
DO 0 (X9.8: enable signal UDC link charged)
DO 1 (X9.11/X9.12: main contactor control)
Signal name
DI 0 (X9.3, external alarm)
DI 1 (X9.4, external fault)
DI 2 (X9.5, Emergency Off category 0)
DI 3 (X9.6, Emergency Off category 1)
Signal name
DI 0 (X9.3, external alarm)
DI 1 (X9.4, external fault)
DI 2 (X9.5, Emergency Off category 0)
DI 3 (X9.6, Emergency Off category 1)
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
High
High
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Simulation
Simulation
Simulation
Simulation
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
High
High
High
High
Parameters
7.3 Parameters
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
0 signal
FP
Low
-
Low
-
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
0000 bin
0 signal
FP
Terminal eval
-
Terminal eval
-
Terminal eval
-
Terminal eval
-
Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
Factory setting:
0000 bin
0 signal
FP
Low
-
Low
-
Low
-
Low
-
661

Advertisement

Table of Contents
loading

Table of Contents