Bi: 2/3 Wire Control Command 2 / 2/3 Wire Cmd 2; Bi: 2/3 Wire Control Command 3 / 2/3 Wire Cmd 3; Co/Bo: 2/3 Wire Control Control Word / 2/3 Wire Stw; Bi: Limit Switch Start / Lim Switch Start - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

Parameters
7.3 Parameters
Dependency:
See also: p0015, p3331, p3332, r3333
Note
The mode of operation of this binector input is dependent on the wire control set in p0015.
p3331[0...n]

BI: 2/3 wire control command 2 / 2/3 wire cmd 2

Access level: 3
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the signal source for command 2 for the two-wire control/three-wire control.
Dependency:
See also: p0015, p3330, p3332, r3333
Note
The mode of operation of this binector input is dependent on the wire control set in p0015.
p3332[0...n]

BI: 2/3 wire control command 3 / 2/3 wire cmd 3

Access level: 3
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the signal source for command 3 for the two-wire control/three-wire control.
Dependency:
See also: p0015, p3330, p3331, r3333
Note
The mode of operation of this binector input is dependent on the wire control set in p0015.
r3333.0...3

CO/BO: 2/3 wire control control word / 2/3 wire STW

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the control word for the two wire control/three wire control.
The control signals are dependent on the wire control set in p0015 and the signal states at the digital inputs.
Bit field:
Bit
00
01
02
03
Dependency:
See also: p0015, p3330, p3331, p3332
p3340[0...n]

BI: Limit switch start / Lim switch start

Access level: 3
Can be changed: T
Unit group: -
Min:
-
Description:
Sets the signal source for the start of motion dependent on the sign of the setpoint.
648
Signal name
ON
Reversing
ON inverted
Reversing inverted
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2272, 2273
Factory setting:
0
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2273
Factory setting:
0
Data type: Unsigned32
Dynamic index: -
Function diagram: 2272, 2273
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: -
Factory setting:
0