Parameters
7.3 Parameters
p11171
Free tec_ctrl 1 actual value inversion / Ftec1 act v inv
Access level: 3
Can be changed: T
Unit group: -
Min:
0
Description:
Sets the inversion of the actual value signal of the free technology controller 1.
Value:
0:
1:
r11172
CO: Free tec_ctrl 1 actual value after limiter / Ftec1 act v af lim
Access level: 2
Can be changed: -
Unit group: 9_3
Min:
- [%]
Description:
Display and connector output for the actual value after the limiter of the free technology controller 1.
r11173
CO: Free tec_ctrl 1 system deviation / Ftec1 sys dev
Access level: 2
Can be changed: -
Unit group: 9_3
Min:
- [%]
Description:
Display and connector output for the system deviation of the free technology controller 1.
p11174
Free tec_ctrl 1 differentiation time constant / Ftec1 D comp T
Access level: 2
Can be changed: T, U
Unit group: -
Min:
0.000 [s]
Description:
Sets the time constant for the differentiation (D component) of the free technology controller 1.
Note
Value = 0: Differentiation is deactivated.
p11180
Free tec_ctrl 1 proportional gain / Ftec1 Kp
Access level: 2
Can be changed: T, U
Unit group: -
Min:
0.000
Description:
Sets the proportional gain (P component) of the free technology controller 1.
Note
Value = 0: The proportional gain is deactivated.
696
No inversion
Inversion
Calculated: -
Scaling: -
Unit selection: -
Max:
1
Calculated: -
Scaling: PERCENT
Unit selection: p11126
Max:
- [%]
Calculated: -
Scaling: PERCENT
Unit selection: p11126
Max:
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max:
60.000 [s]
Calculated: -
Scaling: -
Unit selection: -
Max:
1000.000
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: Integer16
Dynamic index: -
Function diagram: 7030
Factory setting:
0
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7030
Factory setting:
- [%]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7030
Factory setting:
- [%]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7030
Factory setting:
0.000 [s]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7030
Factory setting:
1.000
SINAMICS G120XA converter