p3230[0...n]

CI: Load monitoring speed actual value / Load monit n_act

Access level: 3
Can be changed: T
Unit group: -
Min:
-
Description:
Sets the signal source for the speed actual value of the load monitoring.
Dependency:
See also: r2169, p2181, p2192, p2193, p3231
See also: A07920, A07921, A07922, F07923, F07924, F07925
Note
The parameter is only effective for p2193 = 2.
p3231[0...n]

Load monitoring speed deviation / Load monit n_dev

Access level: 3
Can be changed: T, U
Unit group: 3_1
Min:
0.00 [rpm]
Description:
Sets the permissible speed deviation during load monitoring (for p2193 = 2).
Dependency:
See also: r2169, p2181, p2193, p3230
See also: A07920, A07921, A07922, F07923, F07924, F07925
p3232[0...n]

BI: Load monitoring failure detection / Load_moni fail_det

Access level: 3
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the signal source for detecting a failure.
Dependency:
See also: p2192, p2193
See also: F07936
Note
Monitoring is triggered with a 0 signal, as soon as the time in p2192 has expired.
p3233[0...n]

Torque actual value filter time constant / M_act_filt T

Access level: 3
Can be changed: T, U
Unit group: -
Min:
0 [ms]
Description:
Sets the time constant for the PT1 element to smooth the torque actual value.
The smoothed torque actual value is compared with the threshold values and is only used for messages and signals.
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Calculated: -
Scaling: p2000
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: p0505
Max:
210000.00 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
1000000 [ms]
Parameters
7.3 Parameters
Data type: Unsigned32 /
FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 8012, 8013
Factory setting:
0
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Factory setting:
150.00 [rpm]
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 8013
Factory setting:
1
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 8013
Factory setting:
100 [ms]
643