CDS: Command Data Set
DDS: Drive Data Set
The following control bits are displayed in r0055:
Bit 00: r1198.0
Bit 01: r1198.1
Bit 02: r1198.2
Bit 03: r1198.3
Bit 04: r0837.0
Bit 05: r0837.1
Bit 08: r2349.0 (negated)
Bit 09: r1239.11
Bit 13: r2138.13 (negated)
Bit 15: r0836.1
r0056.0...15

CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Display and BICO output for the status word of the closed-loop control.
Bit field:
Bit
00
01
02
04
05
06
07
08
09
10
11
12
13
14
15
r0060

CO: Speed setpoint before the setpoint filter / n_set before filt.

Access level: 3
Can be changed: -
Unit group: 3_1
Min:
- [rpm]
Description:
Displays the actual speed setpoint at the input of the speed controller or U/f characteristic (after the interpolator).
Dependency:
See also: r0020
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Signal name
Initialization completed
De-magnetizing completed
Pulse enable available
Magnetizing completed
Voltage boost when starting
Acceleration voltage
Frequency negative
Field weakening active
Voltage limit active
Slip limit active
Frequency limit active
Current limiting controller voltage output active
Current/torque limiting
Vdc_max controller active
Vdc_min controller active
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Active
Active
Yes
Yes
Yes
Yes
Yes
Yes
Active
Yes
Yes
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
- [rpm]
Parameters
7.3 Parameters
Data type: Unsigned16
Dynamic index: -
Function diagram: 2526
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
Inactive
6301
Inactive
6301
No
-
No
-
No
6714
No
6310
No
-
No
-
Inactive
6060
No
6220,
6320
No
6220,
6320
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 2701, 6030,
6799, 6822
Factory setting:
- [rpm]
369