Page 3
Voltage Peak Safety information Limiter ___________________ General ___________________ Mechanical installation SINAMICS ___________________ Electrical installation SINAMICS G120P dV/dt filter compact plus Voltage ___________________ Maintenance and servicing Peak Limiter ___________________ Technical specifications Operating Instructions Control version V4.7 04/2016...
Page 4
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Safety information ........................... 7 Warnings ........................... 7 Components that can be destroyed by electrostatic discharge (ESD) ........8 General ..............................11 Mechanical installation .......................... 15 Electrical installation..........................19 Maintenance and servicing ........................27 Technical specifications ........................29 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 6
Table of contents dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Safety information Warnings WARNING Danger to life if the fundamental safety instructions and remaining risks are not carefully observed Non-compliance with the fundamental safety instructions and residual risks stated in Chapter 1 of the Installation Manual for PM330 Power Modules can result in accidents with severe injuries or death.
1.2 Components that can be destroyed by electrostatic discharge (ESD) Note Support by SIEMENS service centers We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. Components that can be destroyed by electrostatic discharge (ESD)
Page 9
Safety information 1.2 Components that can be destroyed by electrostatic discharge (ESD) Image 1-1 ESD protective measures dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 10
Safety information 1.2 Components that can be destroyed by electrostatic discharge (ESD) dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
General Description The du/dt filter compact plus Voltage Peak Limiter comprises two components: the du/dt reactor and the voltage-limiting network (Voltage Peak Limiter), which cuts off the voltage peaks and feeds back the energy into the DC link. The du/dt filter compact plus Voltage Peak Limiter is designed for use with motors for which the voltage strength of the insulation system is unknown or insufficient.
Page 12
Damage to the du/dt filter compact by using components that have not been released When using components that have not been released, damage or malfunctions can occur at the devices or the system itself. • Only use a du/dt filter compact that SIEMENS has approved for operation with SINAMICS. NOTICE...
Page 13
General Assignment of du/dt filter compact plus Voltage Peak Limiter and Power Module Table 2- 1 Assignment of du/dt filter compact plus Voltage Peak Limiter and Power Module Power Module Rated power of the Power Module suitable du/dt filter compact plus Voltage Peak Limiter Line voltage 380 –...
Page 14
General dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Mechanical installation du/dt filter compact plus Voltage Peak Limiter Image 3-1 Dimension drawing of dv/dt filter compact plus Voltage Peak Limiter, article no. 6SL3000-2DE35-0EA0 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 16
Mechanical installation Image 3-2 Dimension drawing of dv/dt filter compact plus Voltage Peak Limiter, article no. 6SL3000-2DE38-4EA0 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 17
Mechanical installation Image 3-3 Dimension drawing of the du/dt filter compact plus Voltage Peak Limiter, Article Nos. 6SL3000-2DE41-4EA0 and 6SL3000-2DG38-1EA0: du/dt reactor dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 18
Mechanical installation Image 3-4 Dimension drawing of the du/dt filter compact plus Voltage Peak Limiter, Article Nos. 6SL3000-2DE41-4EA0 and 6SL3000-2DG38-1EA0: Voltage Peak Limiter dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Electrical installation Interface overview Image 4-1 Interface overview of dv/dt filter compact plus Voltage Peak Limiter, article no. 6SL3000- 2DE35-0EA0 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 20
Electrical installation Image 4-2 Interface overview of dv/dt filter compact plus Voltage Peak Limiter, article no. 6SL3000- 2DE38-4EA0 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 21
Electrical installation Image 4-3 Interface overview of the du/dt filter compact plus Voltage Peak Limiter, Article Nos. 6SL3000-2DE41-4EA0 and 6SL3000-2DG38-1EA0: dv/dt reactor dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 22
Electrical installation Image 4-4 Interface overview of the du/dt filter compact plus Voltage Peak Limiter, Article Nos. 6SL3000-2DE41-4EA0 and 6SL3000-2DG38-1EA0: Voltage Peak Limiter Connection When connecting the du/dt filter compact plus Voltage Peak Limiter, you must take into account the following conditions to ensure that it functions correctly: ●...
Page 23
Electrical installation Connection overview Image 4-5 Connecting the dv/dt filter compact plus Voltage Peak Limiter - integrated unit Image 4-6 Connecting the dv/dt filter compact plus Voltage Peak Limiter - separate components dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 24
Electrical installation Cable cross-sections For du/dt filters with separate Voltage Peak Limiter (Article Nos. 6SL3000-2DE41-4EA0 and 6SL3000-2DG38-1EA0) the connections between du/dt reactor and Voltage Peak Limiter are already attached to the Voltage Peak Limiter. Table 4- 1 Cable cross-sections for connections between a du/dt filter and Power Module du/dt filter compact plus Voltage Peak Limiter Cross-section [mm²]...
Page 25
Electrical installation Tightening torques for screw connections The following tightening torques apply when tightening current-conducting connections (DC link connections, motor connections, busbars, cable lugs) and other connections (ground connections, protective ground connections, steel threaded connections/glands). Table 4- 3 Tightening torques for screw connections Thread Ground connections, protective Aluminum threaded connec-...
Page 26
Electrical installation dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Maintenance and servicing Maintenance and service work cannot be carried out on the du/dt filter compact plus Voltage Peak Limiter. In the case of an error, full replacement is necessary. dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Page 28
Maintenance and servicing dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...
Technical specifications General technical data Table 6- 1 General technical data Product standard EN 61800-5-1 Specific technical data Table 6- 2 Technical data for the dV/dt filter compact plus Voltage Peak Limiter, 380 V – 480 V 3 AC, part 1 Article No.
Page 30
Technical specifications Table 6- 3 Technical data of the dv/dt filter compact plus Voltage Peak Limiter, 380 V ... 480 V 3 AC, Part 2 Article No. 6SL3000- 2DE41-4EA0 1405 thmax Degree of protection IP00 Power loss - At 50 Hz 1.154 - At 60 Hz 1.197...
Page 31
Technical specifications Table 6- 4 Technical data of the du/dt filters plus Voltage Peak Limiter, 3 AC 500 V – 690 V Article number 6SL3000- 2DG38-1EA0 thmax Degree of protection IP00 Power loss - at 50 Hz 0.964 - at 60 Hz 0.998 Max.
Page 32
Technical specifications dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 04/2016, A5E32847614B AC...