Co: Fixed Speed Setpoint 14 / N_Set_Fixed 14; Co: Fixed Speed Setpoint 15 / N_Set_Fixed 15; Fixed Speed Setpoint Select Mode / N_Set_Fix Select; Bi: Fixed Speed Setpoint Selection Bit 0 / N_Set_Fixed Bit 0 - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

p1014[0...n]

CO: Fixed speed setpoint 14 / n_set_fixed 14

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 14.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1015[0...n]

CO: Fixed speed setpoint 15 / n_set_fixed 15

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 15.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1016

Fixed speed setpoint select mode / n_set_fix select

Access level: 2
Can be changed: T
Unit group: -
Min:
1
Description:
Sets the mode to select the fixed speed setpoint.
Value:
1:
2:
Note
For p1016 = 1:
In this mode, the setpoint is entered via the fixed speed setpoints p1001 ... p1004.
Up to 16 different setpoints are obtained by adding the individual fixed speed setpoints.
For p1016 = 2:
In this mode, the setpoint is entered via the fixed speed setpoints p1001 ... p1015.
p1020[0...n]

BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0

Access level: 3
Can be changed: T
Unit group: -
Min:
-
Description:
Sets the signal source for selecting the fixed speed setpoint.
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Direct
Binary
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max:
2
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Parameters
7.3 Parameters
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: Integer16
Dynamic index: -
Function diagram: 3010, 3011
Factory setting:
1
Data type: Unsigned32 / Binary
Dynamic index: CDS, p0170
Function diagram: 2505, 3010,
3011
Factory setting:
0
465

Advertisement

Table of Contents
loading

Table of Contents