Property
Surrounding air temperature dur‐
ing storage
Shock and vibration
Protection against chemical sub‐
stances
Pollution
Sound pressure level L
PA
Cooling method
Cooling air
Maximum sound pressure level, ascertained in the IP20 cabinet
1)
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Explanation
● FSA ... FSG: -40 °C to +70 °C
● FSH/FSJ: -25 °C to +55 °C
● FSA ... FSG
–
Transport in the transport packaging according to Class 2M3 according to EN
61800-5-1 and EN 60068-2-6
–
Vibration in operation according to Class 3M1 according to EN 60721-3-3: 1995
● FSH/FSJ
–
Vibration during operation: Fc test according to EN 60068-2-6 0.075 mm for 10 ...
58 Hz 9.81 m/s² (1 x g) at > 58 ... 200 Hz
–
Shock during operation: Test according to EN 60068- 2-27 100 m/s² (10 x g)/11 ms
–
Vibration during product packaging: Fc test according to EN 60068-2-64 30 min/
axis, 3 axes 10 ... 200 Hz ASD 1.0 (m
–
Shock during product packaging: Fc test according to EN 60068-2-27 10 x g/11 ms
Protected according to 3C2 to EN 60721‑3‑3
Suitable for environments with degree of pollution 2 according to EN 61800-5-1
(1 m)
≤ 76 dB (A)
1)
Air forced cooling
Clean and dry air
11.3 General converter technical data
/s
)
2
3
Technical data
865