p1002[0...n]

CO: Fixed speed setpoint 2 / n_set_fixed 2

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 2.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1003[0...n]

CO: Fixed speed setpoint 3 / n_set_fixed 3

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 3.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1004[0...n]

CO: Fixed speed setpoint 4 / n_set_fixed 4

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 4.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1005[0...n]

CO: Fixed speed setpoint 5 / n_set_fixed 5

Access level: 2
Can be changed: T, U
Unit group: 3_1
Min:
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 5.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
462
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max:
210000.000 [rpm]
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 3010
Factory setting:
0.000 [rpm]