Parameters
7.3 Parameters
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2207[0...n]

CO: Technology controller fixed value 7 / Tec_ctr fix val 7

Access level: 2
Can be changed: T, U
Unit group: 9_1
Min:
-200.00 [%]
Description:
Sets the value for fixed value 7 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2208[0...n]

CO: Technology controller fixed value 8 / Tec_ctr fix val 8

Access level: 2
Can be changed: T, U
Unit group: 9_1
Min:
-200.00 [%]
Description:
Sets the value for fixed value 8 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2209[0...n]

CO: Technology controller fixed value 9 / Tec_ctr fix val 9

Access level: 2
Can be changed: T, U
Unit group: 9_1
Min:
-200.00 [%]
Description:
Sets the value for fixed value 9 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2210[0...n]

CO: Technology controller fixed value 10 / Tec_ctr fix val 10

Access level: 2
Can be changed: T, U
Unit group: 9_1
Min:
-200.00 [%]
Description:
Sets the value for fixed value 10 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
604
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max:
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max:
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max:
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max:
200.00 [%]
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
Factory setting:
70.00 [%]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
Factory setting:
80.00 [%]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
Factory setting:
90.00 [%]
Data type: FloatingPoint32
Dynamic index: DDS, p0180
Function diagram: 7950
Factory setting:
100.00 [%]