7.3 Parameters
r0945[0...63]

Fault code / Fault code

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the numbers of faults that have occurred.
Dependency:
See also: r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3120, r3122
NOTICE
The properties of the fault buffer should be taken from the corresponding product documentation.
Note
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Fault buffer structure (general principle):
r0945[0], r0949[0], r0948[0], r2109[0] --> actual fault case, fault 1
. . .
r0945[7], r0949[7], r0948[7], r2109[7] --> actual fault case, fault 8
r0945[8], r0949[8], r0948[8], r2109[8] --> 1st acknowledged fault case, fault 1
. . .
r0945[15], r0949[15], r0948[15], r2109[15] --> 1st acknowledged fault case, fault 8
. . .
r0945[56], r0949[56], r0948[56], r2109[56] --> 7th acknowledged fault case, fault 1
. . .
r0945[63], r0949[63], r0948[63], r2109[63] --> 7th acknowledged fault case, fault 8
r0946[0...65534]

Fault code list / Fault code list

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Lists the fault codes stored in the drive unit.
The indices can only be accessed with a valid fault code.
Dependency:
The parameter assigned to the fault code is entered in r0951 under the same index.
r0947[0...63]

Fault number / Fault number

Access level: 2
Can be changed: -
Unit group: -
Min:
-
Description:
This parameter is identical to r0945.
r0948[0...63]

Fault time received in milliseconds / t_fault recv ms

Access level: 3
Can be changed: -
Unit group: -
Min:
- [ms]
Description:
Displays the system runtime in milliseconds when the fault occurred.
Dependency:
See also: r0945, r0947, r0949, r2109, r2130, r2133, r2136, p8400
456
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
- [ms]
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8060
Factory setting:
-
Data type: Unsigned16
Dynamic index: -
Function diagram: 8060
Factory setting:
-
Data type: Unsigned16
Dynamic index: -
Function diagram: 8050, 8060
Factory setting:
-
Data type: Unsigned32
Dynamic index: -
Function diagram: 8050, 8060
Factory setting: