FIRMWARE UPDATE PROCEDURE
7. After the firmware update is completed,
"Update done" or "Power Off On" is
displayed. Turn off the main switch and
remove the IC card.
8. If more firmware needs to be
downloaded, make sure that the main
switch is turned off and repeat steps 3
to 6.
9. When all firmware updates are completed, remove the IC card while the
machine power is off and reinstall the IC card cover.
10. Turn the main switch on and confirm that the machine starts normally.
NOTE: Operation Panel Firmware Update
While the firmware of the operation panel
is updating, the operation panel cannot
display anything (this is normal while
firmware update is in process).
The following message is displayed for 10
seconds after pressing the Update button.
Then the message disappears and
firmware update starts.
You can check the firmware update
processing and completion by watching the Start key.
Condition of the Start key
• When the above message disappears, the Start key starts blinking red. This
shows that the machine has started the firmware update, and it takes about 5
minutes.
• When the firmware update is completed, the Start key starts blinking green
instead of red.
G570
PCcard -> ROM Page01
Please do not turn the power off
until start key shows green blinking.
Starting program update of operation panel in few
seconds.
Install time is approximately 5 minutes.
5-88
Update done.
Engine Card No.:1/1
G570S914.WMF
G570S915.WMF