PRINTER ENGINE SERVICE MODE
2
(Class 1, 2, and 3)
223
3
Toner Fill Up
224
[Vcnt / Vref] Vcnt / Vref ([Color])
Adjusts the Vcnt value manually.
The value in this SP mode is effective until after the next process control self-check. To
always use this value for some reason, select proportional control supply mode with SP2-
208-1 to 4.
1
Vcnt [K]
2
Vcnt [Y]
3
Vcnt [M]
4
Vcnt [C]
Adjusts the Vref value manually.
The value in this SP mode is effective until the next process control self-check. To always
use this value for some reason, select proportional control supply mode with SP2-208-1 to
4.
5
Vref [K]
6
Vref [Y]
7
Vref [M]
8
Vref [C]
301
[Transfer Cur.] Transfer Current
([Color Mode, Color], Paper Tray or By-pass, Simplex or Duplex, Process Speed)
Paper Type -> TH: Thick Paper, SP: Special Paper
Adjusts the transfer current for each color and each print mode.
NOTE: If the transfer current is increased too much, image offset may occur especially in
halftone areas.
1
[K]P S 125
2
[K]P S 185
3
[K]P D 125
4
[K]P D 185
5
[K]B S 62.5
6
[K]B S 125
7
[K]B S 185
8
[FC,K]P S 62.5
9
[FC,K]P S 125
10
[FC,Y]P S 62.5
11
[FC,Y]P S 125
12
[FC,M]P S 62.5
13
[FC,M]P S 125
14
[FC,C]P S 62.5
15
[FC,C]P S 125
16
[FC,K]P D 62.5
17
[FC,K]P D 125
18
[FC,Y]P D 62.5
19
[FC,Y]P D 125
G060
Mode No.
#
Function / [ Setting ]
*
Activates or deactivates the Toner Fill Up mode,
which fills up the toner supply tube with toner
during developer initialization.
This function is required only at machine
installation. Although the default is "0", the factory
setting is "1". After toner fill-up occurs during
machine installation, the setting is changed to "0"
automatically.
[ 0 or 1 / 0 / - ] Alphanumeric, DFU
0: Deactivate
1: Activate
*
[ 0 to 220 / 100 / 0.1 V/step ]
NOTE: The main switch must be turned off and on
to effect the setting change.
*
[ 0 to 50 / 28 / 0.1 V/step ]
*
*
*
[ 0 to 50 / 16 / 1 µA/step ]
*
[ 0 to 50 / 24 / 1 µA/step ]
*
[ 0 to 50 / 16 / 1 µA/step ]
*
[ 0 to 50 / 24 / 1 µA/step ]
*
[ 0 to 50 / 8 / 1 µA/step ]
*
[ 0 to 50 / 16 / 1 µA/step ]
*
[ 0 to 50 / 24 / 1 µA/step ]
*
[ 0 to 50 / 6 / 1 µA/step ]
*
[ 0 to 50 / 13 / 1 µA/step ]
*
[ 0 to 50 / 6 / 1 µA/step ]
*
[ 0 to 50 / 11 / 1 µA/step ]
*
[ 0 to 50 / 5 / 1 µA/step ]
*
[ 0 to 50 / 10 / 1 µA/step ]
*
[ 0 to 50 / 6 / 1 µA/step ]
*
[ 0 to 50 / 11 / 1 µA/step ]
*
[ 0 to 50 / 8 / 1 µA/step ]
*
[ 0 to 50 / 16 / 1 µA/step ]
*
[ 0 to 50 / 6 / 1 µA/step ]
*
[ 0 to 50 / 11 / 1 µA/step ]
*
5-18
SM

Advertisement

Table of Contents
loading