PRINTER CONTROLLER SERVICE MODE
(Class 1 and 2)
[Toner Limit]
1
Photo
2
Text
5.2.3 BIT SWITCH PROGRAMMING
NOTE: Currently, the bit switches are not being used except for Bit Switch 2 bit 3,
(See PUB(C)-051 for details) and Bit Switch 3 bit 0 (See PUB(C)-045 for
details).
1. Enter the SP mode, select "Service Menu", then press
[Enter] twice.
2. Select #1, #2, #3, or #4 for the desired bit switch, then
press [Enter].
• [ ] [ ]: Move to the next switch.
3. Adjust the bit switch using the following keys.
• [ ] [ ]: Move to the next bit.
• [Escape]: Exit without saving changes.
• [Enter]: Exit and save changes.
NOTE: The left digit on the display is bit 7 and the right digit is bit 0.
4. Press [Enter] to save changes and exit.
G060
Mode No.
Function / [ Setting ]
*P
Adjusts the maximum toner amount for image
development.
[ 100 to 400 / 260 / 1 %/step ]
[ 100 to 400 / 190 / 1 %/step ]
5-6
Rev. 10/2003
<Service>
Bit Switch >>
Bit Switch
Bit switch 1
Sw#1
00000000
bit0
_
SM