Gestetner G060 Service Manual page 552

Table of Contents

Advertisement

COPY SP MODE
1
(Class 1, 2, and 3)
913
[Temperature Cor. 1] Fusing Temperature Correction (Correction Timing)
1
Sheet Setting
[Temperature Cor. 2] Fusing Temperature Correction (Temperature Setting)
914
1
Heating
2
Pressure
915
[Stand-by Time]
1
Job Receiving
2
Job End
916
[Idling Mode]
1
Mode Set
2
Idling Time
3
Pre-Job Mode
G570
Mode No.
*
BCU
*
BCU
*
BCU
*
BCU
Function / [ Setting ]
Specifies the number of sheets to determine
whether or not to apply the fusing temperature
correction.
During a multi print job, the fusing temperature
tends to slightly overshoot around the 10th sheet
and then stabilize. Temperature overshooting may
cause the glossiness to increase.
To minimize the overshooting, both fusing and
pressure roller temperatures are decreased by the
amount specified in SP1-914 at the number of
sheets specified in this SP mode, until the end of
the job.
[ 1 to 60 / 10 / 1 sheet/step ]
Specifies the temperature to be subtracted from
the targeted temperatures specified in SP1-105-3
to-24.
[ 0 to 30 / 10 / 5°C /step ]
Specifies the time to shift the machine into the
stand-by mode when not receiving a print start
command after receiving a print preparation
command.
[ 0 to 180 / 60 / 10 seconds/step ]
0: The machine does not shift to the stand-by
mode.
Specifies the time to shift the machine into the
stand-by mode after the last job is completed.
[ 0 to 180 / 60 / 10 seconds/step ]
0: The machine does not shift to the stand-by
mode.
Enables or disables fusing unit idling. Idling is
done for the time specified in SP1-916-2 after the
machine enters the ready condition.
[ 0 or 1/ / 0 / - ] DFU
0: OFF
1: ON
Specifies the time for the fusing unit idling.
[10 to 120 / 30 / 10 seconds/step ] DFU
Enables or disables fusing unit idling for 4
seconds before starting a print job.
[ 0 or 1/ / 0 / - ] DFU
0: OFF
1: ON
5-14
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents