Gestetner G060 Service Manual page 766

Table of Contents

Advertisement

BIT SWITCHES
G3 Switch 05
No
FUNCTION
0
Initial Tx modem rate
to
Bit 3 2 1 0 Setting (bps)
3
0 0 0 1 2.4 k
0 0 1 0 4.8 k
0 0 1 1 7.2 k
0 1 0 0 9.6 k
0 1 0 1 12.0 k
0 1 1 0 14.4 k
0 1 1 1 16.8 k
1 0 0 0 19.2 k
1 0 0 1 21.6 k
1 0 1 0 24.0 k
1 0 1 1 26.4 k
1 1 0 0 28.8 k
1 1 0 1 31.2 k
1 1 1 0 33.6 k
Other settings - Not used
4
Initial modem type for 9.6 k or
to
7.2 kbps.
Bit 5 Bit 4
5
0
0
0
1
1
0
1
1
6-7
Not used
G3 Switch 06
No
FUNCTION
0
Initial Rx modem rate
to
Bit 3 2 1 0 Setting (bps)
3
0 0 0 1 2.4 k
0 0 1 0 4.8 k
0 0 1 1 7.2 k
0 1 0 0 9.6 k
0 1 0 1 12.0 k
0 1 1 0 14.4 k
0 1 1 1 16.8 k
1 0 0 0 19.2 k
1 0 0 1 21.6 k
1 0 1 0 24.0 k
1 0 1 1 26.4 k
1 1 0 0 28.8 k
1 1 0 1 31.2 k
1 1 1 0 33.6 k
Other settings - Not used
G307
These bits set the initial starting modem rate for
transmission.
Use the dedicated transmission parameters if you
need to change this for specific receivers.
If a modem rate 14.4 kbps or slower is selected, V.8
protocol should be disabled manually.
Cross reference
V.8 protocol on/off - G3 switch 03, bit2
These bits set the initial modem type for 9.6 and 7.2
kbps, if the initial modem rate is set at these speeds.
Setting
V.29
V.17
V.34
Not used
Do not change the settings.
These bits set the initial starting modem rate for
reception.
Use a lower setting if high speeds pose problems
during reception.
If a modem rate 14.4 kbps or slower is selected, V.8
protocol should be disabled manually.
Cross reference
V.8 protocol on/off - G3 switch 03, bit2
COMMENTS
COMMENTS
3-42
SP No. 1-105-006
SP No. 1-105-007
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents