Switching Between SP Mode and Copy Mode for Test Printing
1) In the SP mode, select the test print and then press Copy Window.
2) Use the copy window (copier mode), to select the appropriate settings
(paper size, etc.) for the test print.
3) Press Start D to execute the test print.
4) Press SP Mode (highlighted) to return to the SP mode screen and repeat
from step 1.
Selecting the Program Number
Program numbers have two or three levels.
1. Before you begin, refer to the Service Tables to find the SP that you want to
adjust. ( 3.1.2)
2. Click the Group number on the left side SP Mode window that contains the SP
that you want to adjust.
3. Use the scrolling buttons in the center of the SP mode window to display the
SP number that you want to open, then press that number to expand the list.
4. Use the center touch-panel buttons to scroll to the number and title of the item
that you want to set and press. The small entry box on the right is activated and
displays the default or the current setting below.
Refer to the Service Tables for the range of allowed settings. ( 3.1.2)
1. To enter a setting:
• Press to toggle between plus and minus, then use the keypad to enter the
appropriate number. The number you enter writes over the previous setting.
• Press  to enter the setting. (If you enter a number that is out of range, the
key press is ignored.)
• When you are prompted to complete the selection, press Yes.
2. When you are finished, press Exit twice to return to the copy window.