MACHINE INSTALLATION
1.5.5 MULTI-BIN OUTPUT TRAY
Accessories Check List
Description
1. Front Tray Holder .................................................................. 1
2. Rear Tray Holder ................................................................... 1
3. Tray ....................................................................................... 2
4. Screw (3 x 1 4) ...................................................................... 4
5. Discharge Brush .................................................................... 2
6. Ground Plate for Left Cover................................................... 1
7. Ground Plate for Upper Exit................................................... 1
8. Ground Plate for Lower Exit................................................... 1
Installing the Multi-Bin Output Tray
NOTE: Before installing the multi-bin output tray, you must install the duplex unit.
1. Open the left cover [A] of the duplex
unit.
2. Install the ground plate [B] behind the
magnet.
3. Install the ground plate [C] on the rear
of the left cover.
4. Attach the ground plate to the top
cover, aligning the bottom edges of
the plate [D] and cover [E].
5. Attach the discharge brushes [F] and
[G] to the upper edges of the paper
exits, so that the ends of the brushes
[H] and [I] touch the ground plates [C]
and [D] respectively.
NOTE: Make sure the brushes do not
obstruct paper coming from the
exits.
G570
[D]
[E]
[C]
[H]
[I]
1-24
Quantity
[B]
G306I101.WMF
[G]
[F]
G306I102.WMF
[A]