SC TABLE
SC No.
Item
SC 734
Finisher tray 2
Tray 2 home position is not
shift motor
detected within a specified
error
time after the tray 2 shift motor
turns on.
SC 818
Watch-dog
While the system program is
error
running, other processes do
not operate at all.
SC 819
Fatal error
[696E]
Process error
System completely down
[766D]
Memory error
Unexpected system memory
size
G060
Definition
Possible Cause
• Loose connection
• Defective tray shift 2
sensor
• Defective tray 2 shift
motor
• Defective controller
• Software error
• Defective RAM DIMM
• Defective ROM DIMM
• Defective controller
• Software error
4-28
Related
Troubleshooting Procedure
SCs
1. Turn the main switch off and on.
2. Check if the connectors of the sensor
and motor are properly connected.
3. Replace the tray shift 2 sensor.
4. Replace the tray 2 shift motor.
1. Turn the main switch off and on.
2. Replace the controller.
3. See NOTE 1 at the end of the SC
table
1. Turn the main switch off and on.
2. Check and/or replace the RAM DIMM.
3. Check and/or replace the ROM
DIMM.
4. Replace the controller.
5. See NOTE at the end of the SC
table.