Gestetner G060 Service Manual page 419

Table of Contents

Advertisement

1. INSTALLATION
1.1 INSTALLATION REQUIREMENTS
1.1.1 ENVIRONMENT
1. Temperature Range:
2. Humidity Range:
3. Ambient Illumination:
4. Ventilation
5. Avoid exposing the machine to sudden temperature changes, which include:
1) Direct cool air from an air conditioner
2) Direct heat from a heater
6. Avoid installing the machine in areas that might be exposed to corrosive gas.
7. Install the machine at a location lower than 2,500 m (8,200 ft.) above sea level.
8. Install the machine on a strong, level base. (Inclination on any side must be no
more than 5 mm.)
9. Avoid installing the machine in areas that may be subjected to strong vibration.
1.1.2 MACHINE LEVEL
Front to back:
Within 5 mm (0.2")
Right to left:
Within 5 mm (0.2")
SM
10 °C to 32 °C (50 °F to 89.6 °F)
15% to 80% RH
Less than 2,000 lux (do not expose to direct sunlight)
3 times/hr/person or more
1-1