Gestetner G060 Service Manual page 214

Table of Contents

Advertisement

PRINTER ENGINE SERVICE MODE
NOTE 1: Memory Clear (SP5-801 & 7-808)
The following tables list the items that are cleared. The serial number information,
meter charge setting (SP5-930), and meter charge counters (SP7-003) are not
cleared.
5
(Class 1, 2, and 3)
[Memory Clear]
801
1
All
2
ENG All
3
SCS
4
IMH
5
MCS
8
PRT
11
NCS
15
ENG Setting
16
ENG Counter
7
808
[Counter Clear]
1
Counter Clear
G060
Mode No.
P
P
P
P
P
P
P
SP Modes or User Setting to be cleared
All items cleared by SP5-801-002, 003, 004, 005,
008, 011, 015, and 016.
All engine related SP modes except for the
following:
• Serial number information
• SP5-930
SP5-009, 101, 104, 305, 812, 833, 961, and 970
SP7-101, 204, 209, 401, 502, 504, 506, and 507
No SP modes are cleared. But, all files stored in
the HDD are cleared.
No SP modes are cleared.
The following service settings:
• Bit switches
• Gamma settings (User & Service)
• Toner Limit
The following user settings:
• Tray Priority
• Menu Protect
• System Setting except for setting of Energy
Saver
• I/F Setup (I/O Buffer and I/O Timeout)
• PCL Menu
All setting of Network Setup (User Menu)
All engine related SP modes except for the
following:
• Serial number information
• SP modes related to meter charge
• Counters and logging data
All counters and logging data related to engine
SP7-101, 204, 209, 502, 504, 506, and 507
5-46
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents