Gestetner G060 Service Manual page 563

Table of Contents

Advertisement

Mode No.
2
(Class 1, 2, and 3)
[Mirror Motor] Mirror Positioning Motor ([Color])
908
Displays the result of the latest line position adjustment. Changing this affects the mirror
position, which corrects the optically skewed image; however, this will be automatically
corrected at the next line position adjustment.
NOTE: If the line position adjustment does not work properly, the line position can be
adjusted manually with this SP mode as a temporary measure. In this case, the
line position adjustment needs to be disabled with SP5-993-001.
2
[C]
3
[M]
4
[Y]
909
[Main-scan Reg.] Main-scan Registration ([Color])
Displays the result of the latest line position adjustment. Changing this affects the main
scan registration; however, this will be automatically corrected at the next line position
adjustment. If a fine adjustment is required, it can be done with SP5-993-010 to 012 (this
affects the way that the adjustment is done, and will be effective from the next line position
adjustment.
NOTE: If the line position adjustment does not work properly, the line position can be
adjusted manually with this SP mode as a temporary measure. In this case, the
line position adjustment needs to be disabled with SP5-993-001.
1 dot = 20µ
1
[Y]
2
[M]
3
[C]
4
[K]
916
[Sub-scan Reg.] Sub-scan Registration ([Color Mode, Color], Resolution)
Displays the result of the latest line position adjustment. Changing this affects the sub
scan registration; however, this will be automatically corrected at the next line position
adjustment. If a fine adjustment is required, it can be done with SP5-993-016 to 021 (this
affects the way that the adjustment is done, and will be effective from the next line position
adjustment.
NOTE: If the line position adjustment does not work properly, the line position can be
adjusted manually with this SP mode as a temporary measure. In this case, the
line position adjustment needs to be disabled with SP5-993-001.
600 dpi: 1 dot = 40µ, 1200dpi: 1 dot = 20µ
1
[K] 1200
2
[FC,K] 1200
3
[FC,Y] 1200
4
[FC,M] 1200
5
[FC,C] 1200
6
[K] 600
7
[FC,K] 600
8
[FC,Y] 600
9
[FC,M] 600
10
[FC,C] 600
[Main Scan Lgth Det] Main-scan Length Detection
919
1
MScan Lgth Det
SM
Function / [ Setting ]
[ -128 to 127 / 0 / 1 pulse/step ] DFU
*
BCU
[ -255 to 255 / 0 / 1 dot/step ] DFU
*
BCU
[ 0 to 20000 / 7510 / 1 dot ] DFU
*
BCU
[ 0 to 20000 / 15038 / 1 dot ] DFU
[ 0 to 20000 / 10402 / 1 dot ] DFU
[ 0 to 20000 / 1136 / 1 dot ] DFU
[ 0 to 20000 / 5762 / 1 dot ] DFU
[ 0 to 20000 / 3755 / 1 dot ] DFU
[ 0 to 20000 / 7519 / 1 dot ] DFU
[ 0 to 20000 / 5201 / 1 dot ] DFU
[ 0 to 20000 / 568 / 1 dot ] DFU
[ 0 to 20000 / 2881 / 1 dot ] DFU
*
Enables or disables the main-scan length
BCU
detection.
[ 0 or 1 / 1 / - ] Alphanumeric
0: Disable
1: Enable
5-25
COPY SP MODE
G570

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents