Gestetner G060 Service Manual page 1082

Table of Contents

Advertisement

Firmware History for G060
DESCRIPTION OF MODIFICATION
The following have been corrected:
SC230 at automatic line position
adjustment
Side effect for firmware version B1.18
SC545 modification (only for G060-17
models): The machine does not display
"Ready" after recovery warm-up from
Energy Saver 1 Mode in phase control
mode.
The following have been corrected:
When SP1-916-1 is set to 1, the machine
may not reach the Ready condition after
the main SW is turned on in low-temp, low-
humidity environments.
Upgrade error recovery cannot be
performed with version 4 of the BCU ASIC
(Gate Array PCI).
The following have been corrected:
SC220-4 for machines with LD unit E-
MAC2 installed.
Destination code for China added.
New SP mode added: SP3-922
(OPU_Refresh2). To activate this function,
it is necessary to use controller firmware
version 2.17 and CF system firmware
version 1.10 or newer.
922
[OPU_Refresh2]
1
2
The following have been corrected:
Paper jam with Series Printing when the
exit tray setting is not the same for all
individual jobs.
Mode_Set
*
Enables or disables the filming removal mode (CMY), which
forcibly creates a temporary 15mm-wide toner line on the drum
surface by applying the development bias and turning on the
development clutch at the end of a job.
[0 to 2/ 0 / -]
0: Disabled
1: Performed at end of job only when ave. pixel cov. ratio of
previous job is low.
2: Performed at end of every job
Bias_Set
*
Development bias setting for filming removal mode (CMY)
[100 to 400/ 200 / 10] DFU
0: OFF, 1: ON
FIRMWARE
SERIAL
LEVEL
NUMBER
G0775623 B
June 2002
G0775623 C
August
2002
G0775623 D
September
2002
G0775623 E
October
2002
FIRMWARE
CHECK
VERSION
SUM
B1.18B
D7B1
B1.19
BB39
B1.21
3F29
B1.22
CCAA
Page 5 of 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents