PRINTER SP MODE
1
105
[Data Save]
1
Data Save
106
[Toner Limit]
1
Toner Limit: Photo
2
Toner Limit: Text
5.3.2 BIT SWITCH PROGRAMMING
⇒
NOTE: Currently, the bit switches are not being used except for Bit Switch 2 bit 3,
(See PUB(C)-051 for details) and Bit Switch 3 bit 0 (See PUB(C)-045 for
details).
1. Press the numeral key (0 to 7) corresponding to the bit number you wish to
change.
Pressing the numeral key changes the setting to either "0" or "1".
NOTE: The left digit on the display is bit 7 and the right digit is bit 0.
2. Press [Enter] to save changes and exit.
G570
Mode No.
(Class 1 and 2)
CTL
Function / [ Setting ]
Stores the print gamma adjusted with the "Gamma
Adj." menu item as the current setting. Before the
machine stores the new 'current setting', it moves the
data currently stored as the 'current setting' to the
'previous setting' memory storage location.
*
Adjusts the maximum toner amount for image
development.
[ 100 to 400 / 260 / 1 %/step ]
[ 100 to 400 / 190 / 1 %/step ]
5-8
Rev. 10/2003
SM