Mode No.
5
(Class 1, 2, and 3)
993
23 Interrupt 2
24 Mscan Lgth Det
[Unit Detection ON/OFF] Maintenance Unit Detection ON/OFF
994
1
Dev. Unit/PCU
2
Oil Supply Unit
[Test Pattern]
997
1
Tray Selection
SM
Function / [ Setting ]
*
Performs the line position adjustment when the
number of prints reaches the number specified in
BCU
this SP mode regardless of the temperature
change.
[ 0 to 350 / 200 / 50 prints/step ]
0: Disable
Performs the main scan length detection when the
polygon motor has operated consecutively for the
time specified in this SP mode.
[ 100 to 990 / 200 / 50 s/step ]
*
Enables or disables PCU and development unit
#
detection.
BCU
[ 0 or 1 / 0 / - ] Alphanumeric
0: Enable
1: Disable
NOTE: If this mode is disabled, new unit detection
also does not function. Use this mode as a
temporary measure, only when the micro-
switches are defective.
*
This is for the oil supply unit only, and not the
#
fusing unit
BCU
[ 0 or 1 / 0 / - ] Alphanumeric
0: Enable
1: Disable
NOTE: Use this mode as a temporary measure,
only when the unit detection mechanism is
defective.
Selects the tray for making a test print.
[ 0 to 4 / 1 / 1/step ]
0: By-pass Table
2: Tray 2
4: Tray 4
NOTE: The machine makes a test pattern on the
paper size loaded in the selected paper
tray.
5-49
COPY SP MODE
1: Tray 1
3: Tray 3
G570