SC No.
Item
SC 554
Pressure roller
During stand-by mode or
fusing lamp
printing, the detected pressure
low
roller temperature stays at 50
temperature
°C or less for five seconds.
error
SC 555
Pressure roller
When the fusing unit is not
fusing lamp
running in the Ready condition,
consecutive
the pressure roller fusing lamp
keeps ON with full power for
full power
100 consecutive seconds.
SC 556
Pressure roller
The pressure roller
temperature changes by ±20
fusing lamp
temperature
°C or more in one second. This
fluctuation
occurs three times in one
minute or two consecutive
times.
SC 560
Zero cross
When the main switch is
error
turned on, the machine checks
how many zero-cross signals
are generated during 500 ms.
If the number of zero-cross
signal generated is either more
than 66 or less than 45 and
when this condition is detected
10 consecutive times, this
code is displayed.
SM
Definition
Possible Cause
• Loose connection
between the fusing
unit and the machine
• Defective pressure
roller thermistor
• Defective PSU
• Defective BCU
• Pressure roller
thermistor out of
position
• Loose connection of
the pressure roller
thermistor
• Loose connection
between the fusing
unit and main frame
• Electrical noise in the
supply from the
power cord
4-23
Related
Troubleshooting Procedure
SCs
1. Check the connection between the
fusing unit and main frame.
2. Replace the fusing unit.
3. Replace the PSU.
4. Replace the BCU.
1. Replace the fusing unit.
1. Check if the fusing unit is properly set
and connected to the main frame.
2. Check if the pressure roller thermistor
connector is firmly connected.
3. Replace the fusing unit.
1. Replace the PSU.
SC TABLE
Type
A
A
A