Gestetner G060 Service Manual page 573

Table of Contents

Advertisement

Mode No.
4
(Class 1, 2, and 3)
[IPU Test Pattern]
417
1
IPU Test Pattern
440
[Saturation Adj.] Saturation Adjustment
1
Saturation Adj.
[R Gain Display] Gain Adjustment Red
628
1
R EVEN
2
R ODD
[G Gain Display] Gain Adjustment Green
629
1
G EVEN
2
G ODD
[B Gain Display] Gain Adjustment Blue
630
1
B EVEN
2
B ODD
[Reference Adj.: R] Reference Adjustment Red
685
1
Reference Adj.: R
[Reference Adj.: G] Reference Adjustment Green
686
1
Reference Adj.: G
[Reference Adj.: B] Reference Adjustment Blue
687
1
Reference Adj.: B
SM
Function / [ Setting ]
Selects the IPU test pattern.
[ 0 to 16 / 0 / 1/step ]
0: Scanned image
1: Grid pattern
2: Slant grid pattern
3: Gradation main scan1
4: Gradation sub scan1
5: Gradation RBGYMCK
6: UCR pattern
7: Color patch 16 (1)
8: Color patch 16 (2)
9: Color patch 64
10: Grid pattern YMCK
11: Color patch YMCK
12: Gray pattern (1)
13: Gray pattern (2)
14: Gradation main scan2
15: Scanned + Grid pattern
16: Scanned + Gray scale
*
Adjusts the level of saturation for copying.
[ 0 to 5 / 3 / 1/step ]
NV
0: High
1: Lowest
2: Lower
3: Default
4: Higher
5: Highest
Displays the gain value of the amplifiers on the
scanner SBU for Red.
Displays the gain value of the amplifiers on the
scanner SBU for Green.
Displays the gain value of the amplifiers on the
scanner SBU for Blue.
*
Sets the reference voltage for the A/D converters
on the scanner IPU for Red.
SBU
[ 0 to 255 / 136 / 1/step ] DFU
*
Sets the reference voltage for the A/D converters
on the scanner IPU for Green.
SBU
[ 0 to 255 / 136 / 1/step ] DFU
*
Sets the reference voltage for the A/D converters
on the scanner IPU for Blue.
SBU
[ 0 to 255 / 136 / 1/step ] DFU
5-35
COPY SP MODE
G570

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents