BULLETIN NUMBER:
APPLICABLE MODEL:
GESTETNER – DSC38/DSC38S
LANIER – 2138AH/2138CMF
RICOH – AP3800C/AP3800CMF
SAVIN – SLP38C/SLP38CS
SUBJECT: NO POWER WHEN THE MAIN SWITCH IS TURNED ON
SYMPTOM:
Power is not supplied when the main switch is turned ON after replacing the PSU [A], Harness - AC Switch
[B] or Bracket – PSU Fan [C].
NOTE:
This may occur on all G060 and G080 series models.
CAUSE:
When replacing the above-mentioned parts, the harness may be damaged when it comes in contact with the
edge of the bracket or PSU bracket.
SOLUTION:
When replacing the PSU, Harness or Bracket, wrap the area of the harness shown by the arrow with
electrical tape to protect it from the bracket edges.
Copyright 2003 RICOH Corporation. All rights reserved.
TECHNICAL SERVICE BULLETIN
G060/G570–033
[A]
[C]
[B]
07/23/2003