Gestetner G060 Service Manual page 736

Table of Contents

Advertisement

BIT SWITCHES
System Switch 02
No
FUNCTION
6
Memory read/write by RDS
7
Bit 7
6
0
0
0
1
1
0
1
1
System Switch 03
No
FUNCTION
0
Length of time that RDS is
to
temporarily switched on when
7
bits 6 and 7 of System Switch
02 are set to "User selectable"
System Switch 04
No
FUNCTION
0-2
Not used
3
Printing dedicated tx
parameters on Quick/Speed
Dial Lists
0: Disabled
1: Enabled
4
Not used
G307
(0,0): All RDS systems are always locked out.
Setting
(0,1), (1,0): Normally, RDS systems are locked out,
Always disabled
but the user can temporarily switch RDS on to allow
User selectable
RDS operations to take place. RDS will
User selectable
automatically be locked out again after a certain
Always enabled
time, which is stored in System Switch 03. Note that
if an RDS operation takes place, RDS will not switch
off until this time limit has expired.
(1,1): At any time, an RDS system can access the
machine.
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System
Switch 02 are set to "User selectable".
The default setting is 24 hours.
Do not change the settings.
1: Each Quick/Speed dial number on the list is
The first 10 bytes of data are the programmed
dedicated tx parameters; 34 bytes of data are
printed (the other 24 bytes have no use for service
technicians).
Do not change the setting.
COMMENTS
COMMENTS
COMMENTS
printed with the dedicated tx parameters (10
bytes each).
3-12
SP No. 1-101-003
SP No. 1-101-004
SP No. 1-101-005
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents