Mode No.
1
(Class 1, 2, and 3)
902
2
Tray 2 B4/LG
3
Tray 2 A4/LT
4
Tray 2 B5/LT
910
[Idling Time] (Fusing Idling Time)
1
Idling Time
912
[Machine Temp.] Machine Temperature Correction
Th: Threshold, Heating or Pressure roller
Corrects the fusing temperature depending on the temperature inside the machine.
If the temperature inside the machine is too high or low, this may cause hot or cold offset
image at the fusing section. To avoid the offset image, the fusing temperature is corrected
depending on the temperature inside machine, which is monitored by the thermistor
located on the right side of the laser optics housing unit.
If the temperature inside the machine is detected as high or low (based on the settings of
SP1-912-001 or 002), the fusing temperature is decreased or increased by the
temperature specified in SP1-912-003 to 006.
1
Th:High Temp
2
Th:Low Temp
3
H:High Temp
4
P:High Temp
5
H:Low Temp
6
P:Low Temp
SM
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
*
Specifies the paper size for tray 2.
[ 0 or 1 / 0 / - ] Alphanumeric
0: B4 lengthwise, 1: LG lengthwise
This specifies which size is detected for a sensor
output of 1101 (see section 6 for details).
US: 1 FA
*
Specifies the paper size for tray 2.
[ 0 or 1 / 0 / - ] Alphanumeric
0: A4 lengthwise, 1: LT lengthwise
This specifies which size is detected for a sensor
output of 0110 (see section 6 for details).
US: 1 FA
*
Specifies the paper size for tray 2.
[ 0 or 1 / 0 / - ] Alphanumeric
0: LT, 1: B5 lengthwise
This specifies which size is detected for a sensor
output of 1011 (see section 6 for details).
*
Specifies the timer for deciding whether to do
fusing idling when receiving a print command.
When receiving a new job within the time specified
in this SP mode after the last job is completed,
fusing idling is not done because the fusing
section was already warmed up during the last
job.
[ 0 to 180 / 1 / 1 minute/step ] DFU
*
Sets the threshold for entering the high
temperature condition.
[ 0 to 50 / 30 / 1°C/step]
*
Sets the threshold for entering the low
temperature condition.
[ 0 to 50 / 17 / 1°C/step]
*
Sets the fusing temperature decrease for the high
temperature condition.
[ 0 to 15 / 0 / 1°C/step]
*
[ 0 to 15 / 0 / 1°C/step]
*
Sets the fusing temperature increase for the low
temperature condition.
[ 0 to 15 / 5 / 1°C/step]
*
[ 0 to 15 / 5 / 1°C/step]
5-11
G060

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents