PRINTER ENGINE SERVICE MODE
2
(Class 1, 2, and 3)
001
21
AC U Limit[FC]
22
AC L Limit[FC]
103
[LD Control] LD Power Control
([Color Mode, Color], Process Speed, K or Color mode) P: Power, M: Magnification
Adjusts the laser power by changing the current applied to LD.
Laser power is automatically adjusted during process control; therefore, adjusting these
data has no effect while Process Control (SP3-125 Default : ON) is activated.
After deactivating Process Control with SP3-125, the values in these SP modes are used
for printing.
1
P0:[FC,K] 62.5
2
P0:[FC,K] 125
4
P0:[FC,Y] 62.5
5
P0:[FC,Y] 125
7
P0:[FC,M] 62.5
8
P0:[FC,M] 125
10
P0:[FC,C] 62.5
11
P0:[FC,C] 125
13
P0:[K,K] 62.5
14
P0:[K,K] 125
15
P0:[K,K] 185
25
P1:[K,K] 62.5
26
P1:[K,K] 125
27
P1:[K,K] 185
Main Scan Magnification ([Color], Laser Exposure Frequency)
55
M:[K] 64.3MHz
56
M:[Y] 64.3MHz
57
M:[M] 64.3MHz
58
M:[C] 64.3MHz
59
M:[K] 47.6MHz
[LD Beam Pitch] LD Beam Pitch
109
Sets the beam pitch for black in 1200 dpi or 600 dpi mode.
NOTE: After replacing the laser optics housing unit, the data printed on the decal attached
to the new unit must be input with this SP mode.
2
Pitch 1200
3
Pitch 600
5
Display 1200
6
Display 600
G060
Mode No.
Function / [ Setting ]
*
Sets the upper limit of the AC component
adjustable range for color.
During machine initialization and process control
self-check, the AC component of the charge roller
bias is automatically adjusted within the range
specified in the SP2-001-021 and 022.
[0 to 255 / 90 / 1/step ] DFU
*
Sets the lower limit of the AC component
adjustable range for color.
[0 to 255 / 84 / 1/step ] DFU
*
[ 0 to 1023 / 672 / 1/step ] DFU
*
[ 0 to 1023 / 640 / 1/step ] DFU
[ 0 to 1023 / 672 / 1/step ] DFU
*
[ 0 to 1023 / 640 / 1/step ] DFU
*
*
[ 0 to 1023 / 672 / 1/step ] DFU
*
[ 0 to 1023 / 640 / 1/step ] DFU
*
[ 0 to 1023 / 672 / 1/step ] DFU
[ 0 to 1023 / 640 / 1/step ] DFU
*
[ 0 to 1023 / 672 / 1/step ] DFU
*
[ 0 to 1023 / 672 / 1/step ] DFU
*
*
[ 0 to 1023 / 601 / 1/step ] DFU
*
[ 0 to 1023 / 672 / 1/step ] DFU
*
[ 0 to 1023 / 672 / 1/step ] DFU
[ 0 to 1023 / 601 / 1/step ] DFU
*
*
Displays the result of the latest line position
adjustment. Changing this affects the main scan
*
magnification; however, this will be automatically
*
corrected at the next line position adjustment. If a
*
fine adjustment is required, it can be done with
*
SP5-993-013 to 015 (this affects the way that the
adjustment is done, and will be effective from the
next line position adjustment).
[ 0 to 280 / 140 / 1 dot/step ] 1 dot = 20µ DFU
NOTE: If the line position adjustment does not
work properly, the line position can be
adjusted manually with this SP mode as a
temporary measure. In this case, the line
position adjustment needs to be disabled
with SP5-993-001.
*
[ 0 to 255 / 50 / 50 pulse/step ] FA
[ 0 to 255 / 42 / 50 pulse/step ] FA
*
[ 0 to 255 / - / 1 pulse/step ]
[ 0 to 255 / - / 1 pulse/step ]
5-14
SM