Gestetner G060 Service Manual page 525

Table of Contents

Advertisement

Rev. 09/2003
SC 991
Software
Performance
Error - Logged
SC 997
Application
function selection
(CF)
error
SC 998
Application start
error
SM
The software performs an
• Incorrect program
unexpected operation.
• Insufficient working
Note: Unlike SC990, the
software/machine continue
to function without requiring
any action.
• The application selected
• Software (including
by the operation panel
key does not start or ends
abnormally.
• An option required by
• Loose connection of
No applications start within
60 seconds after the power
is turned on.
• Defective controller
• Software problem
argument or other
parameter
memory
SC 998
the software
configuration)
defective
the application (RAM,
DIMM, board) is not
installed
RAM-DIMM, ROM-
DIMM
4-43
This SC is not displayed on the LCD
(logged only).
1. Check the devices necessary for the
application program. If necessary
devices have not been installed,
install them.
2. Check that application programs are
correctly configured.
3. Take necessary countermeasures
specific to the application program. If
the logs can be displayed on the
operation panel, see the logs.
1. Turn the main switch off and on.
2. Check if the RAM-DIMM and ROM-
DIMM are properly connected.
3. Reinstall the controller system
firmware.
4. Replace the controller.
SC TABLE
B
B
B
G570

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents