IMAGE ADJUSTMENT
3.3.3 ARDF
ARDF side-to-side and leading edge registration
Make a temporary test chart as shown above using 11 x 17 paper.
1. Place the temporary test chart on the ARDF and make a copy from one of the
feed stations.
2. Check the registration, and adjust using the following SP modes if necessary.
SP Code
SP6-006-1
SP6-006-2
SP6-006-3
SP6-006-4
G570
G570R911.WMF
What It Does
Side-to-Side Registration
Leading Edge Registration (Simplex)
Leading Edge Registration (Duplex: Front)
Leading Edge Registration (Duplex: Back)
A
B
G570R908.WMF
3-4
A: Leading edge registration
B: Side-to-side registration
Adjustment Range
± 1.0 mm
± 2.0 mm
± 4.2 mm
± 4.2 mm
SM