The way that the auto line position adjustment is done can be adjusted using the following
SP modes (SP5-993-010 to 021). These are coefficients used for the adjustment.
Normally, do not change except if the automatic adjustment gives poor results immediately
after installing a new optics housing unit. Change the value then do a forced line position
adjustment (SP 5-993-2) to check the effects of the changes.
Example: If magenta is always shifted one dot to the left, reduce 5-993-11 by 1.
10 M Reg. [Y]
11 M Reg. [M]
12 M Reg. [C]
13 M Mag. [Y]
14 M Mag. [M]
15 M Mag. [C]
16 S Reg. 600[Y]
17 S Reg. 600[M]
18 S Reg. 600[C]
19 S Reg. 1200[Y]
20 S Reg. 1200[M]
21 S Reg. 1200[C]
SM
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
*
Enables or disables the line position adjustment
during stand-by mode when the temperature
differs by the amount specified in SP5-993-003
from the temperature at the last adjustment.
[ 0 or 1 / 0 / - ] Alphanumeric
0: Disabled
1: Enabled
Enables or disables the line position adjustment
just before starting a color print job when the
temperature differs by the amount specified in
SP5-993-003 from the temperature when the
machine woke up from energy saver mode.
[ 0 or 1 / 1 / - ]
0: Disabled
1: Enabled
*
Displays the result of the latest line position
adjustment in 4 digits.
First 2 digits: Error detected on the front ID sensor
Last 2 digits: Error detected on the rear ID sensor
Refer to the Troubleshooting section for more
details about the two-digit codes.
*
Displays how many times the line position
adjustment has been executed.
Counts up by +1 normally.
After a forced adjustment and a PCU
replacement, it counts up +3
Also includes adjustments done at the factory.
*
Displays how many times errors have been
detected during the line position adjustment.
*
A fine adjustment to the main-scan registration.
[ -128 to 127 / 0 / 1 dot/step ] FA
*
1 dot = 20µ
*
*
A fine adjustment to the main-scan magnification.
[ -100 to 100 / 0 / 0.01 %/step ] FA
*
NOTE: The setting changes in this SP mode will
*
be affect the next line position adjustment.
*
A fine adjustment to the sub-scan registration for
each color (color registration).
*
[ -128 to 127 / 0 / 1 dot/step ] FA
*
600dpi: 1 dot = 40µ
*
1200 dpi: 1 dot = 20µ
*
*