BULLETIN NUMBER:
APPLICABLE MODEL:
GESTETNER – DSC38/DSC38S
LANIER – 2138AH/2138CMF
RICOH – AP3800C/AP3800CMF
SAVIN – SLP38C/SLP38CS
SUBJECT: COLOR SHIFT DUE TO ERROR IN INSTALLATION PROCEDURE
SYMPTOM:
Color shift after adjusting the fusing unit line speed at unit replacement.
CAUSE:
Fusing Maintenance Kit Installation Procedure, Offset settings, Step 22:
The two input values (0, 1) for adjusting the fusing roller line speed were reversed. Inputting the values in the
reverse order will cause color shifting to worsen.
Note: The values described in the mainframe Operating Instructions are correct.
PAGE
INCORRECT
Check the test sheets and
make the offset settings for A
A-6
through H. Select "0" for a
STEP 22
white square, and select "1"
for an out-of-register square.
Affected Units:
All Fusing Unit Maintenance Kits produced in 2001 and 2002.
SOLUTION:
The Installation Procedure bundled together with the Fusing Maintenance Kit has been revised from January
1, 2003 kit production.
Action in the Field
User Maintenance:
Please advise customers of the above correction at installation, the next service visit, or when
customers report the symptom due to the above setting error.
Service Maintenance:
Please make note of this correction to ensure the proper values are input.
Copyright     2003 RICOH Corporation. All rights reserved.
TECHNICAL SERVICE BULLETIN
G060/G570 – 034
Check the test sheets and
make the offset settings for A
through H. Select "1" for a
white square, and select "0"
for an out-of-register square.
CORRECT
07/23/2003
Page 1 of 1