Tech Service Bulletin No. G060 – 005
Page 3 of 3
ACTION REQUIRED (in the field)
Please check the following items when installing machines and/or replacing the oil supply unit.
1. Make sure that the carton of the oil supply unit is not stained with oil. If the carton is stained with oil,
replace the oil supply unit with a new one.
2. Open the box and confirm that oil is not leaking anywhere from the unit. If an oil leak is found, replace it
with a new one.
3. Before removing the shield tape ("), confirm if excessive oil has soaked through the oil supply felt by
following procedure below.
(1) Lightly touch the oil supply felt from the top of the shield tape
with your finger.
(2) Check whether you feel that the oil supply felt is soft or hard. If
excessive oil has been soaked through the felt, you will feel
that the oil supply felt is soft.
(3) If excessive oil is noticed, replace the unit with a new one.
4. Position the oil supply unit horizontally and remove the shield tape
("). Check the amount of oil on the oil supply felt. Tilt the unit, If oil
drops form on the felt, replace the unit with a new one.
5. If it is difficult to judge whether the condition of the oil supply felt is
OK or NG, clean the oil supply felt with a clean cloth to remove any
oil on the felt as shown.
6. Make sure that the shield tape (#) has been removed and then
install the oil supply unit onto the fusing unit.
7. Make sure that oil supply unit is properly set and the release
(green) lever is moving freely. (If the release lever stops and does
not return to the original position after pressing and releasing it,
check for the cause of its binding.)