System Switch 04
No
FUNCTION
5
Memory file transfer operation
0: User level
1: Service level
6
G3 CSI/G4 Terminal ID
programming level
0: User level
1: Service level
7
Telephone line type
programming mode
0: User level
1: Service level
System Switch 05 - Not used (Do not change the factory settings.)
System Switch 06
No
FUNCTION
0
Margin setting for Create
to
Margin Transmission
7
System Switch 07 - Not used (Do not change the factory settings.)
System Switch 08 - Not used (Do not change the factory settings.)
SM
COMMENTS
If the machine is unable to print fax messages due
to a mechanical problem, change this bit to 0 to
transfer all messages in the memory (including
confidential rx messages) to an another terminal.
Always reset this bit to 1 after transfer. However,
this bit can be left at 0, if the customer's key-
operators want to transfer the files themselves.
This machine does not support the confidential rx.
Procedure
1. Enter service mode and change this bit to 0.
2. Exit the service mode.
3. Enter the key-operator mode, and select 'Key-
operator settings'.
4. Choose '03' and specify a destination for the
machine to transfer all the files to.
5. Press 'Start'.
6. After the machine transfers the memory files,
enter the service mode and reset this bit to 1.
Otherwise, anybody who knows how to enter the
key-operator mode can transfer confidential
messages.
1: The CSI and Terminal ID can only be
programmed by a technician (in the user tools).
The Terminal ID can only be programmed if a
Group 4 option is installed.
This machine does not have a Group 4 option.
1: Telephone line type selection (choosing tone dial
or pulse dial) can only be programmed by a
technician (in the user tools).
COMMENTS
71 to 99 (BCD) %. This setting determines the
reduction ratio when the user uses the Create
Margin Transmission feature.
Default setting:1001 0011 (93%)