Gestetner G060 Service Manual page 741

Table of Contents

Advertisement

System Switch 11
No
FUNCTION
4
Type of TTI used for
transmission using the ten-key
pad
0: TTI_1
1: TTI_2
5-6
Not used
7
Use of parallel memory
transmission with G4
transmission
0: Disabled 1: Enabled
System Switch 12
No
FUNCTION
0
TTI/CIL printing position in the
to
main scan direction
7
System Switch 13 - Not used (do not change the settings)
System Switch 14 - Not used (do not change the settings)
System Switch 15
No
FUNCTION
0
Not used
1
Going into the Energy Saver
mode automatically
0 : Enabled
1 : Disabled
2-3
Not used
4-5
Interval for preventing the
machine from entering Energy
Saver mode if there is a
pending transmission file.
Bit 5 4
Setting
0
0
1 min
0
1
30 min
1
0
1 hour
1
1
24 hours
6
Print user codes on reports.
0 : Disabled 1 : Enabled
7
Not used
SM
COMMENTS
1: The machine uses TTI_2 when the user dials the
destination using the ten-key pad. It is also used
for polling transmission and manual transmission
using the handset.
Do not change the factory settings.
This determines whether parallel transmission can
be used with a G4 transmission or not.
Note that this bit is only effective if Parallel Memory
transmission is enabled (User Parameter 07 - bit 2).
COMMENTS
TTI/CIL: 08 to 92 (BCD) mm
Input even numbers only.
This setting determines the print start position for
the TTI and CIL from the left edge of the paper. If
the TTI is moved too far to the right, it may overwrite
the file number which is on the top right of the page.
On an A4 page, if the CIL is moved over by more
than 50 mm, it may overwrite the page number.
COMMENTS
Do not change the settings.
1: The machine will restart from the Energy Saver
mode quickly, because the +5V power supply is
active even in the Energy Saver mode.
Do not change the settings.
If there is a file waiting for transmission, the machine
does not go to Energy Saver mode during the
selected period.
After transmitting the file, if there is no file waiting for
transmission, the machine goes to the Energy Saver
mode.
1: User codes are printed out on the Journal or
other reports.
Do not change the settings.
3-17
BIT SWITCHES
SP No. 1-101-018
SP No. 1-101-019
SP No. 1-101-022
G307

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082