MACHINE INSTALLATION
16. Select the language in the UP mode.
17. Set the date and time.
18. Enter SP Mode.
19. Clear the scanner settings by using SP5-801-9.
20. Clear the network application settings by using SP5-801-10.
21. Clear the IPU settings by using SP5-801-12.
22. Exit SP mode and turn the main power off/on.
23. Perform Auto Color Calibration (ACC).
24. Make some test copies in the following modes using a C4 Test Chart.
• Full color in Text Mode
• B&W in Text Mode
25. Check the test copies to make sure each of the following is within standard
values, making any necessary adjustments. ( 3.3 Image Adjustment)
• Leading edge registration
• Side-to-side registration
• Scanner sub-scan magnification
• Scanner leading edge registration
• Scanner side-to-side registration
• ARDF side-to-side registration
• ARDF sheet through registration
26. If necessary, perform the touch panel position adjustment. ( 3.6 Others )
27. If the customer has a service contract, change the meter charge SP mode
settings accordingly.