SC TABLE
SC No.
Item
SC 544
Heating roller
During stand-by mode or a
fusing lamp
print job, the detected heating
low
roller temperature stays at 50
temperature
°C or less for five seconds.
error
SC 545
Heating roller
When the fusing unit is not
fusing lamp
running in the Ready condition,
consecutive
the heating roller fusing lamp
full power
keeps on with full power for 30
consecutive seconds.
SC 546
Heating roller
The heating roller temperature
changes by ±20 °C or more in
fusing lamp
temperature
one second. This occurs three
fluctuation
times in one minute or two
consecutive times.
SC 551
Pressure roller
The measured pressure roller
thermistor
temperature does not reach
error
7°C for 30 seconds.
SC 552
Pressure roller
After the main switch is turned
warm-up error
on or the door is closed, the
pressure roller temperature
does not reach the ready
temperature within 150
seconds during fusing unit
warm-up.
SC 553
Pressure roller
The detected pressure roller
fusing lamp
temperature stays at 200 °C or
overheat
more for five seconds.
G060
Definition
Possible Cause
• Loose connection
between the fusing
unit and the main
frame
• Defective heating
roller thermistor
• Defective PSU
• Defective BCU
• Heating roller
thermistor out of
position
• Loose connection of
the thermistor
• Loose connection
between the fusing
unit and main frame
• Loose connection of
pressure roller
thermistor
• Defective pressure
roller thermistor
• Defective BCU
• Pressure roller fusing
lamp broken
• Defective pressure
roller thermistor
• Defective BCU
• Defective PSU
• Defective BCU
4-22
Related
Troubleshooting Procedure
SCs
1. Check the connection between the
fusing unit and main frame.
2. Replace the fusing unit.
3. Replace the PSU.
4. Replace the BCU.
1. Replace the fusing unit.
1. Check if the fusing unit is properly set
and connected to the main frame.
2. Check if the heating roller thermistor
connector is firmly connected.
3. Replace the fusing unit.
1. Check that the pressure roller
thermistor is firmly connected.
2. Replace the fusing unit.
3. Replace the BCU.
1. Check if the pressure roller thermistor
is firmly connected.
2. Replace the fusing unit.
3. Replace the BCU.
1. Replace the fusing unit.
2. Replace the PSU.
3. Replace the BCU.