MACHINE INSTALLATION
1.5.6 ANTI-CONDENSATION HEATER
1. Remove the rear scale [A] ( x 3).
2. Remove the exposure glass [B] with
the left scale [C] ( x 2).
NOTE: You do not have to remove the
ADF exposure glass. If the glass is
removed, position the glass marker
[D] at the rear-left corner when
reattaching.
3. Remove the rear cover [E] ( x 3).
4. Remove the right cover [F] ( x 3).
5. Remove the left cover [G] ( x 3).
6. Remove the rear frame [H] ( x 12,
x 2).
7. Install the anti-condensation heater [I]
in the rear-left corner of the scanner
unit ( x 2).
8. Pass the cable through the opening [J]
in the rear rail and connect it to the
connector [K] at the front-left corner of
the power supply unit.
9. Reassemble the scanner unit.